Two-compartment technique to remove ophthalmic viscosurgical devices
To avoid postoperative intraocular pressure peaks, complete removal of all ophthalmic viscosurgical devices (OVDs) used during cataract surgery is important. Depending on the kind of OVD used, different removal techniques have been applied. We describe a technique that was used in more than 250 eyes...
Gespeichert in:
Veröffentlicht in: | Journal of cataract and refractive surgery 2000-05, Vol.26 (5), p.641-643 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To avoid postoperative intraocular pressure peaks, complete removal of all ophthalmic viscosurgical devices (OVDs) used during cataract surgery is important. Depending on the kind of OVD used, different removal techniques have been applied. We describe a technique that was used in more than 250 eyes for safe removal of OVDs, especially viscoadaptive OVDs such as sodium hyaluronate 2.3% (Healon®5). It takes advantage of the viscoadaptive properties of Healon5 and was named the 2-compartment technique. |
---|---|
ISSN: | 0886-3350 1873-4502 |
DOI: | 10.1016/S0886-3350(99)00420-4 |