The Influence of Screw Geometry on Hamstring Tendon Interference Fit Fixation
We used a standardized model of calf tibial bone to investigate the influence of screw diameter and length on interference fit fixation of a three-stranded semitendinosus tendon graft for anterior cruciate ligament reconstruction. Biodegradable poly-(L-lactide) interference screws with a diameter of...
Gespeichert in:
Veröffentlicht in: | The American journal of sports medicine 2000-05, Vol.28 (3), p.356-359 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We used a standardized model of calf tibial bone to investigate the influence of screw diameter and length on interference
fit fixation of a three-stranded semitendinosus tendon graft for anterior cruciate ligament reconstruction. Biodegradable
poly-(L-lactide) interference screws with a diameter of 7, 8, and 9 mm and a length of 23 and 28 mm were used. We examined
results in three groups of 10 specimens each: group 1, screw diameter equaled graft diameter and screw length was 23 mm; group
2, screw diameter equaled graft diameter plus 1 mm and screw length was 23 mm; group 3, screw diameter equaled graft diameter
and screw length was 28 mm. The mean pull-out forces in groups 1, 2, and 3 were 367.2 ± 78 N, 479.1 ± 111.1 N, and 537.4 ±
139.1 N, respectively. The force data from groups 2 and 3 were significantly higher than those from group 1. These results
indicate that screw geometry has a significant influence on hamstring tendon interference fit fixation. Increasing screw length
improves fixation strength more than oversizing the screw diameter. This is important, especially for increasing tibial fixation
strength because the tibial graft fixation site has been considered to be the weak link of such a reconstruction. |
---|---|
ISSN: | 0363-5465 1552-3365 |
DOI: | 10.1177/03635465000280031201 |