Recanalization and thrombectomy of internal anastomosis in a patient with tetralogy of Fallot using the AngioJet rheolytic catheter

The modified Blalock‐Taussig shunt is the palliative treatment of choice for tetralogy of Fallot. Shunt thrombosis is a potential complication, requiring high‐risk reoperation. The use of percutaneous rheolytic devices for thrombus removal in such occluded shunts has not been previously reported. We...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Catheterization and cardiovascular interventions 2001-08, Vol.53 (4), p.504-507
Hauptverfasser: Kokov, L.S., Korostelev, A.N., Grinko, A.N., Ilyina, M.V., Solopova, G.V., Aiazian, E., Setum, C.M.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The modified Blalock‐Taussig shunt is the palliative treatment of choice for tetralogy of Fallot. Shunt thrombosis is a potential complication, requiring high‐risk reoperation. The use of percutaneous rheolytic devices for thrombus removal in such occluded shunts has not been previously reported. We describe a case in which use of a rheolytic catheter resulted in significant thrombus removal and rapid reversal of cyanosis and dyspnea in a 5‐year‐old patient. The patient remains free of symptoms at 30‐day follow‐up. Cathet Cardiovasc Intervent 2001;53:504–507. © 2001 Wiley‐Liss, Inc.