Inverse relationship between patient peripheral blood CD34+ cell counts and collection efficiency for CD34+ cells in two automated leukapheresis systems
The purpose of this study was to analyze the CD34 cell collection efficiency (CE) of automated leukapheresis protocols of two blood cell separators (Spectra, COBE [AutoPBSC protocol] and AS104, Fresenius [PBSC-Lym, protocol]) for peripheral blood progenitor cell (PBPC) harvest in patients with malig...
Gespeichert in:
Veröffentlicht in: | Transfusion (Philadelphia, Pa.) Pa.), 2001-08, Vol.41 (8), p.1008-1013 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The purpose of this study was to analyze the CD34 cell collection efficiency (CE) of automated leukapheresis protocols of two blood cell separators (Spectra, COBE [AutoPBSC protocol] and AS104, Fresenius [PBSC-Lym, protocol]) for peripheral blood progenitor cell (PBPC) harvest in patients with malignant diseases.
PBPCs were collected by the Spectra AutoPBSC protocol in 95 patients (123 collections) and the AS104 PBSC-Lym protocol in 87 patients (115 harvests). Patients underwent a median of one (range, 1-4) conventional-volume apheresis procedure of 10.8 L (9.0-13.9) to obtain a target cell dose of > or =2.5 x 10(6) CD34+ cells per kg.
The median overall CD34 CE was significantly better on the AS104 than on the Spectra: 55.8 percent versus 42.4 percent (p = 0.000). This was also true below (59.2% vs. 50.1%; p = 0.022) and above (51.2% vs. 41.3%; p = 0.001) the preleukapheresis threshold of 40 CD34+ cells per microL needed to collect a single-apheresis autograft. However, at > or =40 circulating CD34+ cells per microL, both cell separators achieved the target of > or =2.5 x 10(6) CD34+ cells per kg. The CD34 CE dropped significantly, from 59.2 percent at or =40 cells per microL on the AS104 (p = 0.017) and from 50.1 percent to 41.3 percent on the Spectra (p = 0.033).
Whereas the CD34 CE was significantly different with the AS104 and the Spectra, the CD34 CE of both machines correlated inversely with peripheral blood CD34+ cell counts, showing a significant decline with increasing numbers of circulating CD34+ cells. Nevertheless, at > or 40 preapheresis CD34+ cells per microL, sufficient hematopoietic autografts of > or =2.5 x 10(6) CD34+ cells per kg were harvested by a single conventional-volume (11 L) leukapheresis on both cell separators. |
---|---|
ISSN: | 0041-1132 1537-2995 |
DOI: | 10.1046/j.1537-2995.2001.41081008.x |