Walking with labor epidural analgesia: The impact of bupivacaine concentration and a lidocaine-epinephrine test dose

Regional analgesia techniques for labor that permit ambulation are popular among parturients. This study evaluated the influence of bupivacaine bolus concentration and a 3-ml 1.5% lidocaine-epinephrine test dose, on analgesic effectiveness and the ability to walk after block placement. Using a rando...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Anesthesiology (Philadelphia) 2000-02, Vol.92 (2), p.387-392
Hauptverfasser: COHEN, S. E, YEH, J. Y, RILEY, E. T, VOGEL, T. M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Regional analgesia techniques for labor that permit ambulation are popular among parturients. This study evaluated the influence of bupivacaine bolus concentration and a 3-ml 1.5% lidocaine-epinephrine test dose, on analgesic effectiveness and the ability to walk after block placement. Using a randomized double-blind study design, epidural analgesia was initiated in 60 parturients undergoing labor as follows: Group TD/B.0625 received a 3-ml lidocaine-epinephrine test dose + 12 ml bupivacaine, 0.0625%; group TD/B.125 received a 3-ml test dose + 12 ml bupivacaine, 0.125%; group B.0625 received 15 ml bupivacaine, 0.0625% (no test dose); and group B.125 received 15 ml bupivacaine, 0.125% (no test dose). Initial boluses in all groups contained 10 microg sufentanil. Bupivacaine, 0.0625%, with 0.33 microg/ml sufentanil was infused throughout labor at 13.5-15 ml/h. Analgesia balance, proprioception, motor block, and patient ability to stand and walk were evaluated at various intervals. A bolus of 0.125% bupivacaine containing sufentanil, without a previous test dose, proved to be optimal with respect to analgesia and early ambulation. When a test dose was given before bupivacaine, 0.125%, fewer women walked within 1 h of block placement. Bupivacaine, 0.0625%, with sufentanil, with or without a test dose, provided inadequate analgesia, necessitating additional bupivacaine, which impaired the ability to walk. A high percentage of women in all groups (73-93%) walked at some stage during labor. Omitting a lidocaine-epinephrine test dose and using 0.125% bupivacaine for the initial bolus should permit ambulation in the early postblock period for most parturients who elect this option.
ISSN:0003-3022
1528-1175
DOI:10.1097/00000542-200002000-00019