Transcutaneous Bilirubin Measurement: A Multicenter Evaluation of a New Device

The early discharge of neonates from hospitals makes transcutaneous measurement of total bilirubin concentration a useful tool to monitor neonatal jaundice. The objectives of this study were to determine whether 1) transcutaneous bilirubin (TcB) measurement, as performed using BiliCheck (BC), correl...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Pediatrics (Evanston) 2001-06, Vol.107 (6), p.1264-1271
Hauptverfasser: Rubaltelli, Firmino F, Gourley, Glenn R, Loskamp, Norbert, Modi, Neena, Roth-Kleiner, Matthias, Sender, Alfred, Vert, Paul
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The early discharge of neonates from hospitals makes transcutaneous measurement of total bilirubin concentration a useful tool to monitor neonatal jaundice. The objectives of this study were to determine whether 1) transcutaneous bilirubin (TcB) measurement, as performed using BiliCheck (BC), correlates with total serum bilirubin (TSB) levels, measured with standard laboratory methods and with high-pressure liquid chromatography (HPLC-B); 2) infant race, gestational age, postnatal age, or body weight interferes with the measurement of TcB levels in newborn infants; 3) the variability of the TcB measurement is comparable to the variability of TSB measurements; and 4) TcB measurements obtained from the forehead (BCF) and sternum (BCS) generate comparable results. Newborn infants who were 30 weeks' gestational age and who underwent tests for TSB as part of their normal care in 6 different European hospitals were studied. A total of 210 infants were enrolled in the study, 35 at each site. Near simultaneous (within +/- 30 minutes) blood collection for TSB and BCF and BCS measurements were performed. TSB levels were determined by the serum bilirubin method in use at each site, and all HPLC-B determinations were made at the same, independent laboratory. The study group consisted of 140 white, 31 Asian, 14 Hispanic, 9 African, and another 16 newborns of different races. The correlation coefficient (r) between BCF and HPLC-B was 0.890 (95% confidence interval = 0.858-0.915). BCF and BCS generated similar results (r value = 0.890 for BCF and 0.881 for BCS), even if BCS slightly overestimated (mean error = -0.04 mg/dL) and BCF slightly underestimated (mean error = 0.96 mg/dL) in comparison with HPLC-B. Analysis of covariance demonstrated that BC accuracy was independent of race, birth weight, gestational age, and postnatal age of the newborn. Receiver operating characteristic curves were evaluated for BCF and TSB, each compared with HPLC-B. With the use of a cutoff point for HPLC-B of 13 mg/dL (222 micromol/L) and a cutoff of 11 mg/dL on the BCF and TSB, similar sensitivity/specificity (93%/73% for BCF, 95%/76% for TSB) were observed. The use of a cutoff point for HPLC-B of 17 mg/dL (290 micromol/L) and 14 mg/dL (240 micromol/L) for BCF and TSB also produced similar sensitivity/specificity (90%/87% for the BC and 87%/83% for TSB). Because the correlation coefficient for HPLC-B and BCF is very similar to that found for HPLC-B and laboratory TSB, BC could
ISSN:0031-4005
1098-4275
DOI:10.1542/peds.107.6.1264