Electroretinographic Abnormalities in a Rat Glaucoma Model with Chronic Elevated Intraocular Pressure
The purpose of this study was to determine the ability of electroretinographic (ERG) measurements to document progression of the retinopathy in a rat glaucoma model. Thirty four rats with a chronic intraocular pressure (IOP) elevation induced in one eye by cautery of three episcleral/extra-orbital v...
Gespeichert in:
Veröffentlicht in: | Experimental eye research 2001-06, Vol.72 (6), p.667-677 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The purpose of this study was to determine the ability of electroretinographic (ERG) measurements to document progression of the retinopathy in a rat glaucoma model. Thirty four rats with a chronic intraocular pressure (IOP) elevation induced in one eye by cautery of three episcleral/extra-orbital veins were studied in four separate groups. ERGs were recorded sequentially in Group A rats (n=12) at baseline, and after approximately 20, 40 and 60 days of high IOP, and in three additional groups of rats (n=6 or 10 per group) after approximately 58, 30 and 175 days of high IOP, respectively. Scotopic ERG parameters recorded simultaneously from both eyes in Group A rats were: a- and b-wave amplitudes, implicit times, oscillatory potential amplitudes (OPs) determined at three different light-flash intensities, and the light-adapted (photopic) ERG b-wave amplitude. In the other groups of rats, only scotopic ERG a-wave, b-wave and OP amplitudes were measured.
In Group A rats that were followed sequentially, all the ERG parameters recorded with attenuated stimuli showed significant time-dependent changes in glaucomatous eyes relative to their contralateral normal eyes, with OPs showing the earliest significant difference after only 3 weeks of high IOP. When different groups of unilateral glaucomatous rats were compared beyond 8 weeks of elevated IOP only the OPs showed a continued decrease with time and good discrimination between glaucoma and normal eyes. Over a 25 week period of high IOP the scotopic OPs measured with attenuated light stimuli declined at the rate of approximately 1.5% per week and provided the best ERG measure to monitor progression of retinal pathophysiology in the vein-occlusion rat glaucoma model. |
---|---|
ISSN: | 0014-4835 1096-0007 |
DOI: | 10.1006/exer.2001.1004 |