Single Catheter Determination of Local Electrogram Prematurity Using Simultaneous Unipolar and Bipolar Recordings to Replace the Surface ECG as a Timing Reference

DELACRETAZ, E., et al.: Single Catheter Determination of Local Electrogram Prematurity Using Simultaneous Unipolar and Bipolar Recordings to Replace the Surface ECG as a Timing Reference. Bipolar recordings eliminate much of the far‐field signal, while minimally filtered unipolar recordings contain...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Pacing and clinical electrophysiology 2001-04, Vol.24 (4), p.441-449
Hauptverfasser: DELACRETAZ, ETIENNE, SOEJIMA, KYOKO, GOTTIPATY, VENKATESHWAR K., BRUNCKHORST, CORINNA B., FRIEDMAN, PETER L., STEVENSON, WILLIAM G.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:DELACRETAZ, E., et al.: Single Catheter Determination of Local Electrogram Prematurity Using Simultaneous Unipolar and Bipolar Recordings to Replace the Surface ECG as a Timing Reference. Bipolar recordings eliminate much of the far‐field signal, while minimally filtered unipolar recordings contain substantial far‐field signal components. These properties may allow the onset of the unipolar recording to serve as a timing reference for the bipolar recording obtained from the same electrode catheter during mapping of focal atrial or ventricular tachycardias. Mapping and RF ablation were performed in 26 patients with focal ventricular tachycardia and 14 patients with focal atrial tachycardia. At 205 mapping sites, simultaneous recordings of (1) minimally filtered unipolar electrograms (0.5–500 Hz), (2) high pass filtered unipolar electrograms (100 Hz), and (3) filtered bipolar recordings (30–500Hz) were analyzed. The interval between the onset of the minimally filtered unipolar electrogram and the first peak of the bipolar electrogram (UniOn ‐ Bip) correlated closely with the timing of the local electrogram referenced to the surface ECG (r = 0.85, P < 0.001). Of 53 sites where RF ablation was performed, UniOn ‐ BiP was shorter at successful compared to unsuccessful sites (3.8 ± 3.5 vs 9.2 ± 5.2ms, P < 0.001) and was < 15 ms at all successful sites. In conclusion, the comparison of simultaneous unipolar and bipolar electrograms from a single catheter allows assessment of the prematurity of local electrograms from a focal source without the use of the P wave or QRS onset as a timing reference.
ISSN:0147-8389
1540-8159