Ternary-column system for high-throughput direct-injection bioanalysis by liquid chromatography/tandem mass spectrometry

As a continuation of our efforts to improve our high‐flow on‐line bioanalytical approach for high‐throughput quantitation of drugs and metabolites in biological matrices by high‐performance liquid chromatography (LC) and tandem mass spectrometry (MS/MS), we have developed a ternary‐column on‐line LC...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Rapid communications in mass spectrometry 2000-01, Vol.14 (2), p.105-111
Hauptverfasser: Xia, Yuan-Qing, Whigan, Daisy B., Powell, Mark L., Jemal, Mohammed
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:As a continuation of our efforts to improve our high‐flow on‐line bioanalytical approach for high‐throughput quantitation of drugs and metabolites in biological matrices by high‐performance liquid chromatography (LC) and tandem mass spectrometry (MS/MS), we have developed a ternary‐column on‐line LC/MS/MS system with dual extraction columns used in parallel for purification and an analytical column for analysis. The advantage of the dual extraction column system is that sample analysis can take place in one of the extraction columns while the other column is being equilibrated. Thus, the equilibration time does not add to the run time, hence shortening the injection cycle time and increasing the sample throughput. Moreover, the use of two extraction columns in parallel increases the number of samples that can be injected before the system fails due to an overused extraction column. Such a system has successfully been used to develop and validate a positive ion electrospray LC/MS/MS bioanalytical method for the quantitative determination of a guanidine‐containing drug candidate in rat plasma. The system used for this work utilized two Oasis HLB extraction columns (1 × 50 mm, 30 µm), one C18 analytical column (3.9 × 50 mm, 5 µm), a ten‐port switching value and a tandem mass spectrometer. The on‐line analysis was accomplished by the direct injection of 10 µL of the sample, obtained by mixing a rat plasma sample 1:1 with an aqueous internal standard solution. Selected reaction monitoring (SRM) was utilized for the detection of the analyte and internal standard. The standard curve range was 1.00–200 ng/mL. The intra‐and interday precision and accuracy were within 6.6%. The on‐line purification step lasted for only 0.3 min and total run time was only 1.6 min. Copyright © 2000 John Wiley & Sons, Ltd.
ISSN:0951-4198
1097-0231
DOI:10.1002/(SICI)1097-0231(20000130)14:2<105::AID-RCM842>3.0.CO;2-Q