Redo aortic root surgery for failure of an aortic homograft is a major technical challenge

Objective: Aortic homografts offer many advantages over prosthetic valves. However, homograft dysfunction due to degeneration or infection may lead to reoperation. Aortic valve replacement in patients who have undergone previous aortic root replacement with an aortic homograft remains a technical ch...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of cardio-thoracic surgery 2008-06, Vol.33 (6), p.989-994
Hauptverfasser: Joudinaud, Thomas M., Baron, Franck, Raffoul, Richard, Pagis, Bruno, Vergnat, Mathieu, Parisot, Caroline, Hvass, Ulrik, Nataf, Patrick R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective: Aortic homografts offer many advantages over prosthetic valves. However, homograft dysfunction due to degeneration or infection may lead to reoperation. Aortic valve replacement in patients who have undergone previous aortic root replacement with an aortic homograft remains a technical challenge. To assess reoperation events a retrospective review was conducted. Materials and methods: From January 2000 to October 2006, 20 consecutive patients (38.8 ± 14.9 years old) underwent repeat surgery for aortic homograft failure. Results: Reoperation was performed 7.2 ± 3.5 years after implantation of the aortic homograft as a root. Indication was homograft degeneration (n = 18 [90%]) and endocarditis (n = 2 [10%]). In patients with major homograft wall calcifications or endocarditis, nine aortic root reconstructions were performed (Bentall procedure n = 7; homograft implantation n = 2). Each homograft was dissected with electrical cauterization and removed ‘en-bloc’ sparing the coronary buttons. In case of flexible homograft wall, stented prostheses (mechanical n = 10, bioprosthesis n = 1) were implanted along the homograft annulus. Additional procedures consisted of mitral valve replacements (n = 8), tricuspid repairs (n = 4), Konno procedure (n = 1) and coronary bypass (n = 5). Perioperative complications occurred in seven (35%) patients: sternal re-entry accident (n = 2); reoperations for mediastinitis (n = 1) or bleeding (n = 2); renal insufficiency (n = 1); total heart block (n = 1). No association was found between operative procedures and postoperative complications (Fisher’s exact test). Two patients (10%) died from multiorgan failure in the early postoperative period. In total, 94.4% of the survivors remained free from reoperation at 74 months. Conclusion: Reoperation on patients with an aortic homograft as a root presents a relatively high perioperative morbidity. The surgical strategy depends on the degree of homograft wall calcification.
ISSN:1010-7940
1873-734X
DOI:10.1016/j.ejcts.2008.01.054