Sterile Versus Nonsterile Gloves During Mohs Micrographic Surgery: Infection Rate is not Affected
BACKGROUND: Mohs micrographic surgery (MMS) is an outpatient procedure, which has become the treatment of choice for certain cutaneous malignancies. Although the major steps in this procedure are relatively standardized, one difference involves the use of sterile or nonsterile, clean gloves during t...
Gespeichert in:
Veröffentlicht in: | Dermatologic surgery 2006-02, Vol.32 (2), p.170-176 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | BACKGROUND: Mohs micrographic surgery (MMS) is an outpatient procedure, which has become the treatment of choice for certain cutaneous malignancies. Although the major steps in this procedure are relatively standardized, one difference involves the use of sterile or nonsterile, clean gloves during the tumor removal phase.
OBJECTIVE: This retrospective, chart review study was performed to evaluate whether infection rates are affected by the use of sterile versus nonsterile gloves in the tumor extirpation phase of MMS.
METHODS: This study evaluated the surgical records of 1,810 consecutive Mohs patients, of which 1,239 Mohs patients (1,400 Mohs procedures) met inclusion criteria. Age, sex, tumor diagnosis, anatomic location, number of Mohs stages, area of defect, closure type, cartilage exposure, and sterile versus nonsterile glove use were recorded and evaluated.
RESULTS: Twenty‐five infections were identified. Statistically significant infection rates were discovered for patients with cartilage fenestration with secondary healing and malignant melanoma diagnosis only. There was no statistical difference in infection rates with all other measured variables to include the use of sterile or clean, nonsterile gloves.
CONCLUSION: Our study lends support that clean, nonsterile gloves are safe and effective for use in the tumor extirpation phase of MMS, at a significant cost savings. |
---|---|
ISSN: | 1076-0512 1524-4725 |
DOI: | 10.1111/j.1524-4725.2006.32031.x |