Manifest Refraction Versus Autorefraction for Patients with Subfoveal Choroidal Neovascularization
To compare the results from manifest refraction using trial lenses and a standard visual acuity protocol to results from autorefraction for obtaining refractive error and best corrected visual acuity in patients enrolled in a randomized clinical trial. During a 4-month period, 29 patients with subfo...
Gespeichert in:
Veröffentlicht in: | Investigative ophthalmology & visual science 2001-02, Vol.42 (2), p.447-452 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To compare the results from manifest refraction using trial lenses and a standard visual acuity protocol to results from autorefraction for obtaining refractive error and best corrected visual acuity in patients enrolled in a randomized clinical trial.
During a 4-month period, 29 patients with subfoveal choroidal neovascularization (CNV), who were enrolled in the Submacular Surgery Trials (SSTs) Pilot Study at the Wilmer Ophthalmological Institute, gave verbal consent to participate in this study. Best corrected visual acuity was obtained using Early Treatment Diabetic Retinopathy Study (ETDRS) visual acuity charts and standardized room lighting after performance of manifest refraction, according to the SST protocol, and autorefraction. Refractive error (spherical equivalent) and visual acuity scores were obtained in both eyes of all patients.
On average, manifest refraction gave a spherical equivalent that was 1.04 D more plus than autorefraction (95% limits of agreement = 0.74, 1.34). On average, the visual acuity score was 1.5 letters better after manifest refraction than after autorefraction (95% limits of agreement = 0, 3.0). The comparison of the two methods of refraction was subdivided according to visual acuity level and eye disease (age-related macular degeneration or ocular histoplasmosis syndrome).
Despite large differences in spherical equivalent between manifest refraction and autorefraction, the visual acuity scores were close (mean difference, 1.5 letters). Other studies comparing subjective refraction and autorefraction have shown similar results. Autorefraction in patients with subfoveal CNV may be a satisfactory alternative to manifest refraction in clinical trials and field studies in which best corrected visual acuity is of interest. |
---|---|
ISSN: | 0146-0404 1552-5783 |