Multicenter study of principles-based waveforms for external defibrillation

Study Objective: The efficacy of a shock waveform for external defibrillation depends on the waveform characteristics. Recently, design principles based on cardiac electrophysiology have been developed to determine optimal waveform characteristics. The objective of this clinical trial was to evaluat...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of emergency medicine 2001-01, Vol.37 (1), p.5-12
Hauptverfasser: Bain, Allison C., Swerdlow, Charles D., Love, Charles J., Ellenbogen, Kenneth A., Deering, Thomas F., Brewer, James E., Augostini, Ralph S., Tchou, Patrick J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Study Objective: The efficacy of a shock waveform for external defibrillation depends on the waveform characteristics. Recently, design principles based on cardiac electrophysiology have been developed to determine optimal waveform characteristics. The objective of this clinical trial was to evaluate the efficacy of principles-based monophasic and biphasic waveforms for external defibrillation. Methods: A prospective, randomized, blinded, multicenter study of 118 patients undergoing electrophysiologic testing or receiving an implantable defibrillator was conducted. Ventricular fibrillation was induced, and defibrillation was attempted in each patient with a biphasic and a monophasic waveform. Patients were randomly placed into 2 groups: group 1 received shocks of escalating energy, and group 2 received only high-energy shocks. Results: The biphasic waveform achieved a first-shock success rate of 100% in group 1 (95% confidence interval [CI] 95.1% to 100%) and group 2 (95% CI 94.6% to 100%), with average delivered energies of 201±17 J and 295±28 J, respectively. The monophasic waveform demonstrated a 96.7% (95% CI 89.1% to 100%) first-shock success rate and average delivered energy of 215±12 J for group 1 and a 98.2% (95% CI 91.7% to 100%) first-shock success rate and average delivered energy of 352±13 J for group 2. Conclusion: Using principles of electrophysiology, it is possible to design both biphasic and monophasic waveforms for external defibrillation that achieve a high first-shock efficacy.[Bain AC, Swerdlow CD, Love CJ, Ellenbogen KA, Deering TF, Brewer JE, Augostini RS, Tchou PJ. Multicenter study of principles-based waveforms for external defibrillation. Ann Emerg Med. January 2001;37:5-12.]
ISSN:0196-0644
1097-6760
DOI:10.1067/mem.2001.111690