Clinical advantages of using mini-bypass systems in terms of blood product use, postoperative bleeding and air entrainment: an in vivo clinical perspective

Objective: In an effort to minimize the effect of extracorporeal circulation (ECC), mini-bypass is gaining clinical acceptance in routine coronary artery bypass grafting (CABG). These small circuits target combine the clinical advantages of reduced prime, 100% bio-coating and suction blood separatio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of cardio-thoracic surgery 2007-06, Vol.31 (6), p.1070-1075
Hauptverfasser: Perthel, Mathias, El-Ayoubi, Lémir, Bendisch, Andreas, Laas, Joachim, Gerigk, Markus
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective: In an effort to minimize the effect of extracorporeal circulation (ECC), mini-bypass is gaining clinical acceptance in routine coronary artery bypass grafting (CABG). These small circuits target combine the clinical advantages of reduced prime, 100% bio-coating and suction blood separation. We demonstrate that the use of mini-bypass in routine CABG reduces homologous blood product use and postoperative bleeding. Our goal was to also demonstrate that these small systems are effective in gaseous microemboli (GME) management as compared to a conventional extracorporeal system. Methods: Prospective, randomized study comparing 30 mini-bypass (Dideco ECC.O™) to 30 conventional systems (n = 30, Dideco 903 Avant™). Study included CABG cases only, independent of preoperative coagulative status; clinic ethical committee approval and informed patient consent was obtained before initiating study. Results: There were no statistical differences in terms of patient demographics. Statistically significant differences were seen in transfusion frequency (27% of the study group vs 43% in the control group, p = 0.05), transfused volume (133.3 ± 244.5 ml vs 325 ± 483.1 ml, p ≪ 0.05), fresh frozen plasma (0 unit vs 3 units, p ≪ 0.001), postoperative bleeding (301.8 ± 531.9 ml vs 785.5 ± 1000.4 ml, p ≪ 0.05) and GME activity post-arterial filter (0.14 μl vs 5.32 μl, p ≪ 0.05). Conclusions: The adoption of mini-bypass significantly potentially reduces hemodilution, donor blood usage, postoperative bleeding and exposure to GME in routine CABG patients as compared to the use of conventional extracorporeal circulation circuits.
ISSN:1010-7940
1873-734X
DOI:10.1016/j.ejcts.2007.01.065