Interference-free determination of thallium in aqua regia leaches from rocks, soils and sediments by D(2)-ETAAS method using mixed palladium-citric acid-lithium chemical modifier
The mixture of palladium (chloride) with citric acid and lithium is proposed as a new chemical modifier for the elimination of interference occurred during the determination of Tl in aqua regia extracts from rocks, soils and sediments by electrothermal atomic absorption spectrometry using instrument...
Gespeichert in:
Veröffentlicht in: | Analytica chimica acta 2008-04, Vol.614 (1), p.38-45 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The mixture of palladium (chloride) with citric acid and lithium is proposed as a new chemical modifier for the elimination of interference occurred during the determination of Tl in aqua regia extracts from rocks, soils and sediments by electrothermal atomic absorption spectrometry using instrumentation with deuterium-lamp background correction (D(2)-ETAAS). Palladium was preferred to rhodium and platinum as to analyte stabilization, citric acid served as an effective reducing agent facilitating formation of Pd-Tl stable covalent bonds playing an important role in the analyte stabilization. Citric acid in addition helps to remove most of interfering chloride at low temperature. The further addition of Li increased significantly the robustness of chemical modifier against strongly interfering ZnCl2 matrix by binding free chlorine into a more stable LiCl molecule. In the presence of the proposed chemical modifier the temperature for the final step of pyrolysis was adjustable up to 1000 degrees C, without any noticeable loss of volatile Tl species and the interference of the rest chloride matrix was significantly reduced. The application of the modifier to direct determination of Tl in aqua regia extracts from rocks, soils and sediments has ensured the characteristic mass and LOD value for the original sample 13 pg and 0.043 microg g(-1), respectively (10-microL aliquots of sample) and has enabled the use of matrix-free standard solutions for attaining accurate analysis. The accuracy was verified by the analysis of certified reference samples and by the comparison of results with those found by an inductively coupled plasma orthogonal acceleration time-of-flight mass spectrometer (ICP-oa-TOFMS) method. |
---|---|
ISSN: | 1873-4324 |
DOI: | 10.1016/j.aca.2008.03.012 |