Evaluation of a carbon paste electrode modified with organofunctionalised SBA-15 nanostructured silica in the simultaneous determination of divalent lead, copper and mercury ions
The performance of a carbon paste electrode (CPE) modified with SBA-15 nanostructured silica organofunctionalised with 2-benzothiazolethiol in the simultaneous determination of Pb(II), Cu(II) and Hg(II) ions in natural water and sugar cane spirit ( cachaça) is described. Pb(II), Cu(II) and Hg(II) we...
Gespeichert in:
Veröffentlicht in: | Talanta (Oxford) 2008-03, Vol.75 (1), p.15-21 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The performance of a carbon paste electrode (CPE) modified with SBA-15 nanostructured silica organofunctionalised with 2-benzothiazolethiol in the simultaneous determination of Pb(II), Cu(II) and Hg(II) ions in natural water and sugar cane spirit (
cachaça) is described. Pb(II), Cu(II) and Hg(II) were pre-concentrated on the surface of the modified electrode by complexing with 2-benzothiazolethiol and reduced at a negative potential (−0.80
V). Then the reduced products were oxidised by DPASV procedure. The fact that three stripping peaks appeared on the voltammograms at the potentials of −0.48
V (Pb
2+), −0.03
V (Cu
2+) and +0.36
V (Hg
2+) in relation to the SCE, demonstrates the possibility of simultaneous determination of Pb
2+, Cu
2+ and Hg
2+. The best results were obtained under the following optimised conditions: 100
mV pulse amplitude, 3
min accumulation time, 25
mV
s
−1 scan rate in phosphate solution pH 3.0. Using such parameters, calibration graphs were linear in the concentration ranges of 3.00–70.0
×
10
−7
mol
L
−1 (Pb
2+), 8.00–100.0
×
10
−7
mol
L
−1 (Cu
2+) and 2.00–10.0
×
10
−6
mol
L
−1 (Hg
2+). Detection limits of 4.0
×
10
−8
mol
L
−1 (Pb
2+), 2.0
×
10
−7
mol
L
−1 (Cu
2+) and 4.0
×
10
−7
mol
L
−1(Hg
2+) were obtained at the signal noise ratio (SNR) of 3. The results indicate that this electrode is sensitive and effective for simultaneous determination of Pb
2+, Cu
2+ and Hg
2+ in the analysed samples. |
---|---|
ISSN: | 0039-9140 1873-3573 |
DOI: | 10.1016/j.talanta.2007.06.032 |