Volumetric Assessment of Epicardial Adipose Tissue With Cardiovascular Magnetic Resonance Imaging
OBJECTIVE: Previous studies determined the amount of epicardial fat by measuring the right ventricular epicardial fat thickness. However, it is not proven whether this one-dimensional method correlates well with the absolute amount of epicardial fat. In this prospective study, a new cardiovascular m...
Gespeichert in:
Veröffentlicht in: | Obesity (Silver Spring, Md.) Md.), 2007-04, Vol.15 (4), p.870-878 |
---|---|
Hauptverfasser: | , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | OBJECTIVE: Previous studies determined the amount of epicardial fat by measuring the right ventricular epicardial fat thickness. However, it is not proven whether this one-dimensional method correlates well with the absolute amount of epicardial fat. In this prospective study, a new cardiovascular magnetic resonance imaging (CMR) method using the three-dimensional summation of slices method was introduced to assess the total amount of epicardial fat. RESEARCH METHODS AND PROCEDURES: CMR was performed in 43 patients with congestive heart failure and in 28 healthy controls. The absolute amount of epicardial fat was assessed volumetrically in consecutive short-axis views by means of the modified Simpson's rule. Additionally, the right ventricular epicardial fat thickness was measured in two different imaging planes: long-axis view (EFT-4CV) and consecutive short-axis views (EFT-SAX). RESULTS: Using the volumetric approach, patients with congestive heart failure had less epicardial fat mass than controls (51 g vs. 65 g, p = 0.01). This finding was supported by EFT-SAX (2.9 mm vs. 4.3 mm, p < 0.0001) but not by EFT-4CV (3.5 mm vs. 3.8 mm, p = not significant). Epicardial fat mass correlated moderately with EFT-SAX in both groups (r = 0.466, p = 0.012 in controls and r = 0.590, p < 0.0001 in patients) and with EFT-4CV in controls (r = 0.387, p = 0.042). There were no significant differences between EFT-4CV and EFT-SAX in controls (4.3 mm vs. 3.8 mm, p = 0.240). However, in the heart failure group, EFT-4CV was significantly higher compared with EFT-SAX (3.5 mm vs. 2.9 mm, p = 0.003). Interobserver variability and reproducibility were superior for the volumetric approach compared with thickness measurements. DISCUSSION: Quantitative assessment of epicardial fat mass using the CMR-based volumetric approach is feasible and yields superior reproducibility compared with conventional methods. |
---|---|
ISSN: | 1930-7381 1930-739X |
DOI: | 10.1038/oby.2007.591 |