Effects of a Novel Sterilization Process on Soft Tissue Mechanical Properties for Anterior Cruciate Ligament Allografts

Background: Allograft anterior cruciate ligament reconstruction provides benefits such as earlier return to activities and less pain, but concerns remain regarding potential infection and biomechanical stability. Hypothesis: There is no difference in biomechanical properties of soft tissue allograft...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The American journal of sports medicine 2007-04, Vol.35 (4), p.612-616
Hauptverfasser: Schimizzi, Aimee, Wedemeyer, Michelle, Odell, Tim, Thomas, Walter, Mahar, Andrew T., Pedowitz, Robert
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background: Allograft anterior cruciate ligament reconstruction provides benefits such as earlier return to activities and less pain, but concerns remain regarding potential infection and biomechanical stability. Hypothesis: There is no difference in biomechanical properties of soft tissue allografts treated with the Biocleanse tissue sterilization process compared with irradiated and fresh-frozen allografts. Study Design: Controlled laboratory study. Methods: Thirty-six tibialis anterior allografts were equally divided between Biocleanse, irradiated, and fresh-frozen groups. Grafts were measured for cross-sectional area and looped over a smooth rod with the free sutured ends of the graft fixed in custom clamps. Specimens were tensioned to 10 N for 2 minutes and then loaded between 50 and 300 N for 1000 cycles followed by a failure test. Data for creep (mm); stiffness (N/mm) at cycles 1, 10, 100, and 1000; failure load (N); and failure stress (MPa) were compared with a one-way analysis of variance ( P < .05). Results: There were no statistically significant differences in creep between groups. Sterilized groups (irradiated = 144.7 ± 17.7 N/mm and Biocleanse = 146.5 ± 28.2N/mm) were significantly stiffer during the first cycle than the fresh-frozen group (117.8 ± 15.7 N/mm, P < .005) without statistically significant differences for subsequent cycles. There were no differences between groups for either failure load (fresh-frozen = 1665 ± 291.3 N, irradiated = 1671.9 ± 290.2 N, Biocleanse = 1651.6 ± 377.4 N) or failure stress. Conclusion: Data for “time-zero” physiologic stiffness and failure loads indicate that the Biocleanse process does not adversely affect the biomechanical properties of the allograft material. Clinical Relevance: This novel sterilization technique may provide surgeons with potential allograft material with similar biomechanical properties to native tissue. Keywords: anterior cruciate ligament reconstruction allograft sterilization biomechanical stability
ISSN:0363-5465
1552-3365
DOI:10.1177/0363546506295083