The effect of on-body lift assistive device on the lumbar 3D dynamic moments and EMG during asymmetric freestyle lifting

Abstract Background A new on-body personal lift assistive device was developed to reduce force requirements of back muscles during lifting and static holding tasks. Methods Nine male subjects participated in the study. Twelve Fastrak™ sensors were used to record positions and rotations of the segmen...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Clinical biomechanics (Bristol) 2008-03, Vol.23 (3), p.372-380
Hauptverfasser: Abdoli-E, Mohammad, Stevenson, Joan M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Background A new on-body personal lift assistive device was developed to reduce force requirements of back muscles during lifting and static holding tasks. Methods Nine male subjects participated in the study. Twelve Fastrak™ sensors were used to record positions and rotations of the segments. Trunk muscles were normalized to maximum and integrated electromyographic amplitudes of the left and right thoracic erector spinae, lumbar erector spinae, external obliques, and rectus abdominalis were compared in asymmetrical lifting for three different loads (5 kg, 15 kg, 25 kg) using free style under two conditions: with and without a lift assistive device. Findings The assistive device significantly reduced the required muscular effort of the lumbar and thoracic erector spinae ( P = 0.001) with no significant differences in the level of abdominal muscular activity. Average integrated electromyography amplitudes were reduced across all subjects by 23.9% for lumbar erector spinae, 24.4% for thoracic erector spinae, and 34.9% for the contralateral external oblique muscles. The assistive device had its greatest impact on smaller moments with 30% reduction in lateral bending, and 24% reduction in rotational moments, with only 19.5% a reduction in larger flexion–extension moments. To investigate whether the lift assistive device affected lifting kinematics, the device tensions were zeroed mathematically. No kinematic differences in lifting technique would explain this magnitude of moment reduction. Interpretation The on-body assistive device reduced the required muscular effort of the lumbar and thoracic erector spinae without adversely affecting the level of abdominal muscle activity. These reductions were mirrored by similar 3D moment reductions.
ISSN:0268-0033
1879-1271
DOI:10.1016/j.clinbiomech.2007.10.012