The obstacles to maximising the impact of public access defibrillation: an assessment of the dispatch mechanism for out-of-hospital cardiac arrest

Objectives:To determine the diagnostic accuracy of advanced medical priority dispatch system (AMPDS) software used to dispatch public access defibrillation first responders to out-of-hospital cardiac arrests (OHCA).Design:All true OHCA events in North and West Belfast in 2004 were prospectively coll...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Heart (British Cardiac Society) 2008-03, Vol.94 (3), p.349-353
Hauptverfasser: Cairns, K J, Hamilton, A J, Marshall, A H, Moore, M J, Adgey, A A J, Kee, F
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectives:To determine the diagnostic accuracy of advanced medical priority dispatch system (AMPDS) software used to dispatch public access defibrillation first responders to out-of-hospital cardiac arrests (OHCA).Design:All true OHCA events in North and West Belfast in 2004 were prospectively collated. This was achieved by a comprehensive search of all manually completed Patient Report Forms compiled by paramedics, together with autopsy reports, death certificates and medical records. The dispatch coding of all emergency calls by AMPDS software was also obtained for the same time period and region, and a comparison was made between these two datasets.Setting:A single urban ambulance control centre in Northern Ireland.Population:All 238 individuals with a presumed or actual OHCA in the North and West Belfast Health and Social Services Trust population of 138 591 (2001 Census), as defined by the Utstein Criteria.Main outcome measures:The accurate dispatch of an emergency ambulance to a true OHCA.Results:The sensitivity of the dispatch mechanism for detecting OHCA was 68.9% (115/167, 95% confidence interval (CI) 61.3% to 75.8%). However, the sensitivity for arrests with ventricular fibrillation (VF) was 44.4% (12/27) with sensitivity for witnessed VF of 47.1% (8/17). The positive predictive value was 63.5% (115/181, 95% CI 56.1% to 70.6%).Conclusions:The sensitivity of this dispatch process for cardiac arrest is moderate and will constrain the effectiveness of Public Access Defibrillation (PAD) schemes which utilise it.Trial registration:controlled-trials.com ISRCTN 07286796.
ISSN:1355-6037
1468-201X
DOI:10.1136/hrt.2006.109785