The effect of load cycling on metal ceramic screw-retained implant restorations with unrestored and restored screw access holes

Statement of problem It has been shown that under cyclic loading, more chipping fractures of the veneer ceramic occur on the occlusal surface of screw-retained implant-supported fixed partial dentures (FPDs) with unrestored screw access holes (SAHs) than in cemented restorations. This lack of stabil...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of prosthetic dentistry 2008, Vol.99 (1), p.19-24
Hauptverfasser: Karl, Matthias, DMD, Graef, Friedrich, MSD, Wichmann, Manfred G., DMD, Heckmann, Siegfried M., DMD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Statement of problem It has been shown that under cyclic loading, more chipping fractures of the veneer ceramic occur on the occlusal surface of screw-retained implant-supported fixed partial dentures (FPDs) with unrestored screw access holes (SAHs) than in cemented restorations. This lack of stability may result in esthetic and functional problems. Purpose The purpose of this study was to investigate whether, under dynamic loading, fewer chipping fractures occur on the occlusal surface of screw-retained ceramic veneered implant FPDs with restored SAHs than in those with unrestored SAHs. Material and methods Twenty screw-retained ceramic veneered 5-unit FPDs were manufactured for a 3-implant situation and divided into 2 groups of 10 unrestored and 10 SAHs restored with adhesive composite resin restorations (Tetric Evo Ceram). A masticatory simulator was used to load the FPDs occlusal to the implant positions for 20,000 cycles with a force of 100 N applied for 1 second, followed by 1 second of no loading. Three prosthodontists evaluated the FPDs using a light microscope and a dental probe. The number of chipping fractures found were analyzed using a generalized linear model with Poisson response and log link function (α =.05). Results Investigators found significantly more chipping fractures in the group of screw-retained FPDs with unrestored SAHs. The rate ratio of unrestored versus restored prostheses was 3.29 ( P =.006). Conclusions Adhesive composite resin restorations can significantly reduce the number of chipping fractures occurring around the SAHs of screw-retained implant-supported restorations.
ISSN:0022-3913
1097-6841
DOI:10.1016/S0022-3913(08)60004-9