Analytical Evaluation of Particle-Enhanced Immunonephelometric Assays for C-Reactive Protein, Serum Amyloid a and Mannose-Binding Protein in Human Serum

Against a background of growing interest in more sensitive assays for quantifying various acute phase proteins, we evaluated the performance of recently developed tests for C-reactive protein (CRP), serum amyloid A (SAA) and mannose-binding protein (MBP) on the Behring nephelometer II (BN II). Sampl...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Annals of clinical biochemistry 1998-11, Vol.35 (6), p.745-753
Hauptverfasser: Ledue, Thomas B, Weiner, Debra L, Sipe, Jean D, Poulin, Sue E, Collins, Marilyn F, Rifai, Nader
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Against a background of growing interest in more sensitive assays for quantifying various acute phase proteins, we evaluated the performance of recently developed tests for C-reactive protein (CRP), serum amyloid A (SAA) and mannose-binding protein (MBP) on the Behring nephelometer II (BN II). Sample results outside the calibration ranges of 3·5 to 220 mg/L for CRP, 3·3 to 215 mg/L for SAA and 0·09 to 5·6 mg/L for MBP were automatically re-measured at another dilution. The lower limits of detection were 0·01, 0·7 and 0·01 mg/L for CRP, SAA and MBP, respectively. The coefficients of variation (CV) for intra- (n ⩾ 20) and inter- (n ⩾ 15) assay precision were < 5·2% and < 8·5%, respectively, for the three proteins at concentrations representing low, normal and high. Linearity for each method was within 5% of the expected values throughout the calibration range. We observed no significant interference from bilirubin (up to 300 mg/L) or haemoglobin (up to 10 g/L) for the three tests. Method comparison studies performed for CRP and SAA yielded the following results: y (CRP on BN II) = 0·75x (ELISA, Hemagen) −0·25 mg/L (r = 0·981, Sy/x = 2·1 mg/L; y (SAA on BN II) = 1·44x (ELISA, Hemagen) −9·9 mg/L (r = 0·972, Sy/x = 6·9 mg/L), where ELISA is enzyme-linked immunosorbent assay. Reference intervals established in 261 adult blood donors (aged 36·2 ± 9·0 years) were found to be log-normal with 2·5th, 50th and 97·5th centiles of < 0·17, 100 and 10·1 mg/L for CRP, < 0·84, 2·10 and 9·70 mg/L for SAA; and 0·30, 1·28 and 4·10 mg/L for MBP. We observed no relationship with CRP concentration and age; however, SAA levels increased with age while MBP levels decreased. The BN II provides a simple, rapid and sensitive system for measuring CRP, SAA and MBP in human serum.
ISSN:0004-5632
1758-1001
DOI:10.1177/000456329803500607