A rational algorithm for duplex scan surveillance after carotid endarterectomy

Purpose: This study was undertaken to determine the appropriate timing and frequency of duplex ultrasound scanning after carotid endarterectomy (CEA) for the detection of high-grade stenosis caused by recurrent carotid stenosis or contralateral atherosclerotic disease progression. Methods: In 221 pa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of vascular surgery 1999-09, Vol.30 (3), p.453-460
Hauptverfasser: Roth, Steven M., Back, Martin R., Bandyk, Dennis F., Avino, Anthony J., Riley, Victoria, Johnson, Brad L.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose: This study was undertaken to determine the appropriate timing and frequency of duplex ultrasound scanning after carotid endarterectomy (CEA) for the detection of high-grade stenosis caused by recurrent carotid stenosis or contralateral atherosclerotic disease progression. Methods: In 221 patients who underwent 242 CEAs, duplex scanning was performed before, during, and after operation (in 3-month to 6-month intervals). High-grade internal carotid artery (ICA) stenosis (peak systolic velocity, >300 cm/s; diastolic velocity, >125 cm/s; ICA/common carotid artery ratio, >4) prompted the recommendation for repair. An average of four postoperative scanning procedures was performed during a mean follow-up period of 27.4 months. Results: Intraoperative duplex scan results prompted the immediate revision of 12 repairs (4.9%), and one perioperative stroke (50% diameter-reduction [DR]; systolic velocity, >125 cm/s) develop. Only one of six patients had >75% DR stenosis develop and underwent reoperation (75% DR stenosis was five times as frequent ( P =.002) in patients with >50% DR stenosis initially. All patients but one who required contralateral endarterectomy for disease progression had >50% ICA stenosis when first seen. During the follow-up period, no disabling strokes ipsilateral to an operated carotid artery occurred, but three strokes occurred in the hemisphere of the contralateral unoperated ICA. Conclusion: The yield of duplex scan surveillance after CEA was low. Only 13 patients (5.9%) had severe disease develop to warrant additional intervention. Progression of contralateral disease rather than restenosis was the most common abnormality that was identified. Duplex scanning at 1-year to 2-year intervals after CEA is adequate when a technically precise repair is achieved and minimal contralateral disease (
ISSN:0741-5214
1097-6809
DOI:10.1016/S0741-5214(99)70072-8