Activation-induced T-cell death and immune dysfunction after implantation of left-ventricular assist device

Cardiac transplantation is a limited option for end-stage heart failure because of the shortage of donor organs. Left-ventricular assist devices (LVADs) are currently under investigation as permanent therapy for end-stage heart failure, but long-term successful device implantation is limited because...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Lancet (British edition) 1999-08, Vol.354 (9178), p.550-555
Hauptverfasser: ANKERSMIT, H. J, TUGULEA, S, OZ, M. C, ITESCU, S, SPANIER, T, WEINBERG, A. D, ARTRIP, J. H, BURKE, E. M, FLANNERY, M, MANCINI, D, ROSE, E. A, EDWARDS, N. M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Cardiac transplantation is a limited option for end-stage heart failure because of the shortage of donor organs. Left-ventricular assist devices (LVADs) are currently under investigation as permanent therapy for end-stage heart failure, but long-term successful device implantation is limited because of a high rate of serious infections. To examine the relation between LVAD-related infection and host immunity, we investigated immune responses in LVAD recipients. We compared the rate of candidal infection in 78 patients with New York Heart Association class IV heart failure who received either an LVAD (n=40) or medical management (controls, n=38). Fluorochrome-labelled monoclonal antibodies were used in analyses of T-cell phenotype. Analysis of T-cell function included intradermal responses to recall antigens and proliferative responses after stimulation by phytohaemagglutinin, monoclonal antibodies to CD3, and mixed lymphocyte culture. We measured T-cell apoptosis in vivo by annexin V binding, and confirmed the result by assessment of DNA fragmentation. Activation-induced T-cell death was measured after T-cell stimulation with antibodies to CD3. All immunological tests were done at least 1 month after LVAD implantation. Between-group comparisons were by Kaplan-Meier actuarial analysis and Student's t test. By 3 months after implantation of LVAD, the risk of developing candidal infection was 28% in LVAD recipients, compared with 3% in controls (p=0.003). LVAD recipients had cutaneous anergy to recall antigens and lower (
ISSN:0140-6736
1474-547X