Endovascular repair of stent graft collapse by stent-protected angioplasty using a femoral-brachial guidewire
This report aims to describe an effective endovascular technique to repair a stent graft collapse in the distal aortic arch. We report a case of a stent graft collapse after off-label endovascular treatment of a traumatic aortic transection using a Gore TAG endoprosthesis (oversizing 12%). The colla...
Gespeichert in:
Veröffentlicht in: | Journal of vascular surgery 2008-12, Vol.48 (6), p.1609-1612 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | This report aims to describe an effective endovascular technique to repair a stent graft collapse in the distal aortic arch. We report a case of a stent graft collapse after off-label endovascular treatment of a traumatic aortic transection using a Gore TAG endoprosthesis (oversizing 12%). The collapse was treated by off-label stent-protected angioplasty (Palmaz stent, Cordis, Miami, Fla) over a stiff guidewire, which was passed from the right femoral artery through the collapsed stent graft and out at the right brachial artery. We believe that this technique enables more precise stent deployment and is safer than the regular guidewire position in the ascending aorta. |
---|---|