Left ventricular outflow tract obstruction with mitral mechanical prosthesis

Left ventricular outflow tract obstruction after mitral valve replacement may occur when the native mitral apparatus is preserved intact. Although it has usually been reported using bioprostheses, we present one case using a low-profile mechanical prosthesis. The reduction of left ventricular dimens...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 1999-07, Vol.68 (1), p.255-257
Hauptverfasser: Melero, José M, Rodriguez, Isabel, Such, Miguel, Porras, Carlos, Olalla, Eduardo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Left ventricular outflow tract obstruction after mitral valve replacement may occur when the native mitral apparatus is preserved intact. Although it has usually been reported using bioprostheses, we present one case using a low-profile mechanical prosthesis. The reduction of left ventricular dimensions and valvular redundancy contributed to this complication. We obtained definitive relief of left ventricular outflow tract obstruction by transaortic exposure and partial resection of the obstructing tissue with the help of video-assisted cardioscopy.