Pseudoaneurysm of the abdominal aorta: evaluation with virtual angioscopy of spiral-CT data sets

We describe a case of graft-related pseudoaneurysm of the abdominal aorta evaluated with spiral CT and DSA. Spiral CT data sets were processed to obtain surface-rendered internal views (virtual angioscopy, VA) of the graft and the pseudoaneurysm, and to demonstrate from inside the lumen the site of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European radiology 1999-01, Vol.9 (6), p.1227-1230
Hauptverfasser: Neri, E, Caramella, D, Cioni, R, Trincavelli, F, Vignali, C, Bartolozzi, C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We describe a case of graft-related pseudoaneurysm of the abdominal aorta evaluated with spiral CT and DSA. Spiral CT data sets were processed to obtain surface-rendered internal views (virtual angioscopy, VA) of the graft and the pseudoaneurysm, and to demonstrate from inside the lumen the site of dehiscence. A jet flow phenomenon inside the pseudoaneurysm was observed at DSA. Spiral-CT axial images, multiplanar volume reconstructions with maximum intensity projections, and shaded surface display showed the site of rupture. The VA findings were: (a) from inside the graft lumen, the evidence of a communication canal between the graft and the pseudoaneurysm; and (b) from inside the pseudoaneurysm, the presence of a jet flow. The VA findings showed good correlation with those obtained with the other imaging techniques.
ISSN:0938-7994
1432-1084
DOI:10.1007/s003300050823