Detrimental effects of speckle-pixel size matching in laser speckle contrast imaging
Through a series of simulations and experiments, we demonstrate that the frequently cited criterion of matching speckle size to detector element (pixel) size in laser speckle contrast imaging (LSCI) has the detrimental effect of reducing the contrast and thereby decreasing the variation in the laser...
Gespeichert in:
Veröffentlicht in: | Optics letters 2008-12, Vol.33 (24), p.2886-2888 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Through a series of simulations and experiments, we demonstrate that the frequently cited criterion of matching speckle size to detector element (pixel) size in laser speckle contrast imaging (LSCI) has the detrimental effect of reducing the contrast and thereby decreasing the variation in the laser speckle contrast image. Unlike quasi-elastic light scattering, where this matching condition has been shown to maximize the signal-to-noise ratio, in LSCI, the minimum speckle size must exceed the Nyquist criterion in order to maximize the contrast of the speckle patterns. |
---|---|
ISSN: | 0146-9592 1539-4794 |
DOI: | 10.1364/ol.33.002886 |