Discrimination of damaged/dead cells by propidium iodide uptake in immunofluorescently labeled populations analyzed by phase-sensitive flow cytometry

We report a flow cytometric fluorescence lifetime-based method to discriminate damaged/dead from viable cells in immunofluorescently labeled populations using propidium iodide as a dye-exclusion viability probe. Fluorescence signals from propidium iodide and the anti-thymus cell-surface immunofluore...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of immunological methods 1999-06, Vol.226 (1), p.59-70
Hauptverfasser: Steinkamp, John A, Lehnert, Bruce E, Lehnert, Nancy M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We report a flow cytometric fluorescence lifetime-based method to discriminate damaged/dead from viable cells in immunofluorescently labeled populations using propidium iodide as a dye-exclusion viability probe. Fluorescence signals from propidium iodide and the anti-thymus cell-surface immunofluorescence marker fluorochromes, phycoerythrin and phycoerythrin/Texas Red (tandem conjugate), which have overlapping emission spectra with propidium iodide, are resolved based on differences in their fluorescence emission lifetimes using phase-sensitive detection. Mouse thymus cell samples were first labeled separately with anti-Thy 1.2 antibody directly conjugated to phycoerythrin and to phycoerythrin/Texas Red and propidium iodide. Labeled cells were then analyzed to determine the lifetimes of the immunofluorescence markers and propidium iodide. Based on these results, rat and mouse thymocytes labeled with anti-Thy 1.1 conjugated to phycoerythrin and anti-Thy 1.2 conjugated to phycoerythrin/Texas Red, respectively, were suspended in phosphate buffered saline containing propidium iodide, and were analyzed as they passed through a flow chamber and crossed a high-frequency, intensity-modulated (sinusoidal) laser excitation beam. The resulting immunofluorescence and propidium iodide signals were resolved based on differences in fluorescence lifetimes expressed as phase shifts using phase-sensitive detection and displayed as frequency distribution histograms and bivariate contour diagrams. This technology provides a new method to resolve immunofluorescence and propidium iodide signals from overlapping fluorescence emission spectra and a flow cytometric lifetime-based technique to quantify damaged/dead cells in immunofluorescence studies.
ISSN:0022-1759
1872-7905
DOI:10.1016/S0022-1759(99)00053-8