Hemodynamic sensing using subcutaneous photoplethysmography

St. Jude Medical, Sylmar, California Submitted 30 May 2008 ; accepted in final form 29 September 2008 Pacemakers and implantable defibrillators presently operate without access to hemodynamic information. If available, such data would allow tailoring of delivered therapy according to perfusion statu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of physiology. Heart and circulatory physiology 2008-12, Vol.295 (6), p.H2560-H2572
Hauptverfasser: Turcott, Robert G, Pavek, Todd J
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:St. Jude Medical, Sylmar, California Submitted 30 May 2008 ; accepted in final form 29 September 2008 Pacemakers and implantable defibrillators presently operate without access to hemodynamic information. If available, such data would allow tailoring of delivered therapy according to perfusion status, optimization of device function, and enhancement of disease monitoring and management. A candidate method for hemodynamic sensing in these devices is photoplethysmography (PPG), which uses light to noninvasively detect changes in blood volume. The present study tested the hypotheses that PPG can function in a subcutaneous location, that the acute changes in blood volume it detects are directly proportional to changes in arterial pressure, and that optimum pacing intervals identified by it are concordant with those determined by arterial pressure. Aortic pressure and PPG were simultaneously recorded in 10 dogs under general anesthesia during changes in atrioventricular (AV) delay and bursts of rapid pacing to simulate tachyarrhythmias. Direct proportionality between transient changes in pressure and PPG waveforms was tested using regression analysis. Scatter plots had a linear appearance, with correlation coefficients of 0.95 (SD 0.03) and 0.72 (SD 0.24) for rapid-pacing and AV delay protocols, respectively. The data were well described by a directly proportional relationship. Optimum AV delays estimated from the induced changes in aortic pressure and PPG waveforms were concordant. This preliminary canine study demonstrates that PPG can function subcutaneously and that it may serve as a surrogate for acute changes in arterial pressure. defibrillator; pacemaker; sensor; atrioventricular delay; arrhythmia Address for reprint requests and other correspondence: R. Turcott, Stanford Univ. Medical Center, Division of Cardiovascular Medicine, Falk CVRC; MC 5406, Stanford, CA 94305-5406 (e-mail: turcott{at}stanford.edu )
ISSN:0363-6135
1522-1539
DOI:10.1152/ajpheart.00574.2008