Stability of Stabilized 99mTc-D,L-HMPAO Stored in Vials and Syringes
Our objective was to determine the stability of stabilized (99m)Tc-hexamethylpropylene amine oxime ((99m)Tc-d,l-HMPAO) dispensed by vial and syringe, with the storage time and labeling activity varied. (99m)Tc-d,l-HMPAO was labeled according to the manufacturer's instructions, but with modifica...
Gespeichert in:
Veröffentlicht in: | Journal of nuclear medicine technology 2008-12, Vol.36 (4), p.213-216 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Our objective was to determine the stability of stabilized (99m)Tc-hexamethylpropylene amine oxime ((99m)Tc-d,l-HMPAO) dispensed by vial and syringe, with the storage time and labeling activity varied.
(99m)Tc-d,l-HMPAO was labeled according to the manufacturer's instructions, but with modification of the (99m)TcO(4)Na activity. Two groups were prepared: 1,110 MBq (30 mCi) and 2,600-3,700 MBq (70.3-100 mCi). Five minutes after labeling, the radiochemical purity (RCP) of the vial content was determined. Afterward, the same activity was distributed into two 2-mL syringes and into the manufacturer's vial. In one of the syringes, the radiopharmaceutical stayed in contact with the needle for 4 h. At 2 and 4 h after labeling, the RCP of the vial and syringe content was checked and compared.
The mean RCP of stabilized (99m)Tc-d,l-HMPAO labeled with 1,110 MBq (30 mCi) and stored in a vial decreased from 93.1% at 5 min to 92.1% at 2 h and to 91.1% at 4 h. With storage in a syringe, the RCP decreased from 89.8% at 2 h to 88.7% at 4 h. This diminution increased for labeling with higher activities (2,600-3,700 MBq [70.3-100 mCi]), ranging from 91.4% at 5 min, 89.0% at 2 h, and 85.3% at 4 h in a vial and from 85.9% at 2 h to 80.2% in a syringe. (99m)TcO(2) and secondary (99m)Tc-HMPAO were the main impurities at t = 0. (99m)TcO(4)(-) was an impurity that increased with time in both vials and syringes but significantly so in syringes. All these impurities were higher with labeling activities in the range of 2,600-3,700 MBq (70.3-100 mCi). Contact of the needle with (99m)Tc-d,l-HMPAO sharply decreased the RCP to 57.1% at 4 h.
The RCP of stabilized (99m)Tc-d,l-HMPAO decreases significantly in both vials and syringes with high labeling activities. The product is less stable when stored in a syringe than in a vial. The fraction of dose in contact with the needle affects the RCP results. |
---|---|