Fluorescein test for the detection of striae in the corneal flap after laser in situ keratomileusis

PURPOSE: To report a technique for detecting striae in the corneal flap after laser in situ keratomileusis. METHODS: Fluorescein dye was instilled in the eye, and the patient was asked to blink. The tear film was examined at the slit lamp with the cobalt filter 1 or 2 seconds after blinking. RESULTS...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:American journal of ophthalmology 1999-06, Vol.127 (6), p.717-718
Hauptverfasser: Rabinowitz, Yaron S, Rasheed, Karim
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:PURPOSE: To report a technique for detecting striae in the corneal flap after laser in situ keratomileusis. METHODS: Fluorescein dye was instilled in the eye, and the patient was asked to blink. The tear film was examined at the slit lamp with the cobalt filter 1 or 2 seconds after blinking. RESULTS: The uneven pattern of pooling in the tear film was a sensitive indicator of the presence of striae in the flap. CONCLUSION: This technique may be useful in detecting minimal striae in the corneal flap in patients with unexplained suboptimal visual acuity after laser in situ keratomileusis.
ISSN:0002-9394
1879-1891
DOI:10.1016/S0002-9394(98)00421-8