Sensor modulation transfer function measurement using band-limited laser speckle

A new methodology for image sensor modulation transfer function measurement using band-limited laser speckle is presented. We use a circular opal milk glass diffuser illuminated by a 5 mW He-Ne laser and a linear polarizer to generate band-limited speckle on the sensor. The power spectral density cu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Optics express 2008-11, Vol.16 (24), p.20047-20059
Hauptverfasser: Chen, Xi, George, Nicholas, Agranov, Gennadiy, Liu, Changmeng, Gravelle, Bob
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A new methodology for image sensor modulation transfer function measurement using band-limited laser speckle is presented. We use a circular opal milk glass diffuser illuminated by a 5 mW He-Ne laser and a linear polarizer to generate band-limited speckle on the sensor. The power spectral density cut-off frequency of the speckle is chosen to be twice that of the sensor Nyquist frequency by placing the sensor at the specific Z location along the optical axis. For the speckle input, we calculate the power spectral density at the sensor using the Rayleigh-Sommerfeld integral and then measure the output power spectral density for the speckle pattern captured by the sensor. With these data, the two-dimensional image sensor modulation transfer function (MTF) is calculated.
ISSN:1094-4087
1094-4087
DOI:10.1364/OE.16.020047