Background: Conventional T2-weighted (T2-WI) magnetic resonance imaging (MRI) has poor sensitivity for prostate transition-zone (TZ) cancer detection. Purpose: To retrospectively evaluate the clinical value of diffusion-weighted MRI (DW-MRI) and dynamic contrast-enhanced MRI (DCE-MRI) in combination...
Gespeichert in:
Veröffentlicht in: | Acta radiologica (1987) 2008-12, Vol.49 (10), p.1207-1213 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background: Conventional T2-weighted (T2-WI) magnetic resonance imaging (MRI) has poor sensitivity for prostate transition-zone (TZ) cancer detection.
Purpose: To retrospectively evaluate the clinical value of diffusion-weighted MRI (DW-MRI) and dynamic contrast-enhanced MRI (DCE-MRI) in combination with T2-WI for the diagnosis of TZ cancer.
Material and Methods: Twenty-six TZ cancers in 23 patients with at least one tumor (tumor size >10 mm) located predominantly in the TZ were included in the study. Sixteen peripheral-zone (PZ) cancers in 12 patients with PZ cancer but without TZ cancer (control group) were selected by step-section pathologic maps. All patients underwent MRI and radical prostatectomy. MRI was obtained by a 1.5T superconducting system with a phased-array coil. Imaging sequences were T2-WI with fat saturation (FST2-WI), DW-MRI (single-shot echoplanar image, b=0 and 1000 s/mm2, apparent diffusion coefficient [ADC] map findings), and DCE-MRI (3D fast spoiled gradient recalled [SPGR], contrast medium [0.2 mmol/kg], total injection time 5 s, image acquisition 30, 60, and 90 s). Sensitivity, specificity, accuracy, and positive predictive value (PPV) for the diagnosis of TZ cancer were evaluated in four protocols: A) FST2-WI alone, B) FST2-WI plus DW-MRI, C) FST2-WI plus DCE-MRI, D) FST2-WI plus DW-MRI plus DCE-MRI.
Results: Sensitivity, specificity, accuracy, and PPV in protocol A (FST2-WI alone) were 61.5%, 68.8%, 64.3%, and 76.2%, respectively. FST2-WI plus DW-MRI (protocol B) improved the sensitivity, specificity, accuracy, and PPV. In FST2-WI plus DW-MRI plus DCE-MRI (protocol D), the number of true-negative lesions increased and false-positive lesions decreased, and the sensitivity, specificity, accuracy, and PPV were 69.2%, 93.8%, 78.6%, and 94.7%, respectively. There was a significant difference between protocols A and D (P |
---|---|