Urinary screening tests for fetal Down syndrome: I. Fresh β-core fragment

Variable results have been reported using urine β‐core fragment as a marker for fetal Down syndrome. Initial studies by Cuckle et al. (1994) and Canick et al. (1995) indicated that β‐core fragment was an outstanding marker, detecting >80 per cent of Down syndrome cases. Since these reports, widel...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Prenatal diagnosis 1999-04, Vol.19 (4), p.340-350
Hauptverfasser: Cole, Laurence A., Rinne, Kirsi M., Mahajan, Smita M., Oz, Utku A., Shahabi, Shohreh, Mahoney, Maurice J., Bahado-Singh, Ray O.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Variable results have been reported using urine β‐core fragment as a marker for fetal Down syndrome. Initial studies by Cuckle et al. (1994) and Canick et al. (1995) indicated that β‐core fragment was an outstanding marker, detecting >80 per cent of Down syndrome cases. Since these reports, widely varying results have been published, indicating between 20 per cent and 66 per cent detection of cases at 5 per cent false‐positive rate. The wide variation in the reported data has led to a loss of enthusiasm for this marker as a useful test for Down syndrome screening. Here we report the results of a three‐year prospective study in which urine samples were collected daily from women undergoing fetal karyotype analysis for advanced maternal age. Samples were tested within one week of collection and then frozen. We also investigated the likely causes of the variability observed in β‐core fragment data. We collected 1157 urine samples over 955 days. β‐core fragment levels were measured. A regression line was calculated for the weekly medians of the 1134 control samples and multiples of the control median (MoM) were determined. The median MoM for the controls was 1.0 and the logarithmic standard deviation (log SD) was 0.41. The median MoM for the 23 Down syndrome cases was 5.44 and the log SD was 0.45. Over the study period, 65 per cent of Down syndrome cases exceeded the 95th centile of the control group. The median MoM of control samples and the proportion of Down syndrome cases detected by the test was relatively constant during the study period. The unaffected cases were divided into three equal divisions, corresponding to approximately the first, second and third year of sample collection. No trend was found in the median control MoM values in three sample collection periods (r2=0.04). A similar number of cases exceeded the 95th centile of control samples in the three sample collection periods, 63 per cent, 66 per cent and 66 per cent. Consistent results were indicated during the three years of sample testing. Levels of total oestriol were determined in urine samples and MoM statistics derived. The median oestriol level in Down syndrome cases was 0.59 MoM. Only 12 per cent of cases had MoM levels below the fifth centile. Gaussian models were prepared combining biochemical data and maternal age distribution. While β‐core fragment by itself detected 65 per cent of Down syndrome cases, β‐core fragment modelled with maternal age detected 66 per cent, and modelled
ISSN:0197-3851
1097-0223
DOI:10.1002/(SICI)1097-0223(199904)19:4<340::AID-PD543>3.0.CO;2-9