Innominate vein cannulation for venous drainage in minimally invasive aortic valve replacement
Minimally invasive aortic valve or aortic root replacement may be carried out through a mini-hemisternotomy. Venous cannulation of the right atrium may be difficult, at best, and obstruct the limited operative field. We have carried out cannulation of the innominate vein with 25F or 27F thin-walled...
Gespeichert in:
Veröffentlicht in: | The Annals of thoracic surgery 1999-03, Vol.67 (3), p.864-865 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Minimally invasive aortic valve or aortic root replacement may be carried out through a mini-hemisternotomy. Venous cannulation of the right atrium may be difficult, at best, and obstruct the limited operative field. We have carried out cannulation of the innominate vein with 25F or 27F thin-walled femoral venous cannulae in 20 patients. Transesophageal echocardiographic guidance is invaluable in safely passing the guidewire and subsequently the cannula into the right atrium. This approach results in an unobtrusive method of complete intrathoracic cannulation through a mini-hemisternotomy with the risks of femoral cannulation. |
---|---|
ISSN: | 0003-4975 1552-6259 |
DOI: | 10.1016/S0003-4975(99)00071-5 |