Aortobifemoral prosthetic infection treated by cryopreserved arterial homografts of the European Homograft Bank

The excision of an infected aortobifemoral Dacron graft 9 years after implantation and bilateral axillofemoral Dacron bypass reconstruction led to reinfection of the extra-anatomic bypass grafts. A new aortobifemoral reconstruction was performed using cryopreserved homografts delivered by the Europe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:VASA 1999-02, Vol.28 (1), p.42-45
Hauptverfasser: SCHROEDER, A, MEIERLING, S, RIEPE, G, BRAUN, S, IMIG, H
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The excision of an infected aortobifemoral Dacron graft 9 years after implantation and bilateral axillofemoral Dacron bypass reconstruction led to reinfection of the extra-anatomic bypass grafts. A new aortobifemoral reconstruction was performed using cryopreserved homografts delivered by the European Homograft Bank in Brussels and both axillo-femoral prostheses were removed. No signs of infection and no alterations of the homografts can be detected 3 years later.