A pitfall of transfix fixation during anterior cruciate ligament reconstruction
While attempting femoral fixation during anterior cruciate ligament (ACL) reconstruction using Bio-TransFix (Arthrex, Naples, FL), we experienced failure of complete insertion of a hamstring graft into the femoral tunnel. A passing wire was twisted in the femoral tunnel during insertion of the ACL g...
Gespeichert in:
Veröffentlicht in: | Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA sports traumatology, arthroscopy : official journal of the ESSKA, 2008-05, Vol.16 (5), p.479-481 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | While attempting femoral fixation during anterior cruciate ligament (ACL) reconstruction using Bio-TransFix (Arthrex, Naples, FL), we experienced failure of complete insertion of a hamstring graft into the femoral tunnel. A passing wire was twisted in the femoral tunnel during insertion of the ACL graft. The cause and methods of prevention of this complication are discussed. |
---|---|