Experimental Assessment of Proximal Stent-graft (InterVascularTM) Fixation in Human Cadaveric Infrarenal Aortas

Objectivesthis paper investigates the radial deformation load of an aortic endoluminal prosthesis and determines the longitudinal load required to cause migration in a human cadaveric aorta of the endoprosthesis.Design and methodsthe endovascular prosthesis under investigation was a 24 mm diameter,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of vascular and endovascular surgery 1999-01, Vol.17 (1), p.60-65
Hauptverfasser: Lambert, A.W, Williams, D.J, Budd, J.S, Horrocks, M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objectivesthis paper investigates the radial deformation load of an aortic endoluminal prosthesis and determines the longitudinal load required to cause migration in a human cadaveric aorta of the endoprosthesis.Design and methodsthe endovascular prosthesis under investigation was a 24 mm diameter, nitinol, self-expanding aortoaortic device (InterVascular, Clearwater, Florida, U.S.A.). Initially, a motorised digital force gauge developed an incremental load which was applied to the ends of five stent-grafts, to a maximum of 10 mm (42%) compression. Secondly, using a simple bench model, each end of four stent-grafts were deployed into 10 cadaveric experimental aneurysm necks and a longitudinal load applied to effect distraction.Resultsincreasing load produced increasing percentage deformation of the stent-grafts. The mean longitudinal distraction load for an aneurysm neck of 20 mm was 409 g (200–480 g), for 15 mm was 277 g (130–410 g) and for 10 mm was 218 g (130–340 g). The aneurysm diameter and aortic calcification hadpvalues of 0.002 and 0.047, respectively, while thepvalue for aneurysm neck length was less than 0.00001.Conclusionsthese results suggest that there is a theoretical advantage of oversizing an aortic prosthesis and that sufficient anchorage is achieved in an aortic neck of 10 mm to prevent migration when fully deployed.
ISSN:1078-5884
1532-2165
DOI:10.1053/ejvs.1998.0711