Two-to-One AV Block Associated with the Congenital Long QT Syndrome
2:1 AV Block in LQTS. Introduction Conduction abnormalities associated with long QT syndrome (LQTS) have been reported as “pseudo 2:1 AV block” due to sinus intervals shorter than ventricular refractoriness. Method and Results: We report the electrophysiologic characteristics of a patient suffering...
Gespeichert in:
Veröffentlicht in: | Journal of cardiovascular electrophysiology 1999-01, Vol.10 (1), p.108-113 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | 2:1 AV Block in LQTS. Introduction Conduction abnormalities associated with long QT syndrome (LQTS) have been reported as “pseudo 2:1 AV block” due to sinus intervals shorter than ventricular refractoriness.
Method and Results: We report the electrophysiologic characteristics of a patient suffering from congenital LQTS with episodes of true 2:1 AV block. Induction of 2:1 infra‐Hisian blocks and return to 1:1 conduction were observed using single atrial and ventricular extrastimuli. The block was located in the Purkinje network but not in the myocardium.
Conclusion: The His‐Purkinje system of our LQTS patient displayed dynamic properties with a strong increase in refractoriness for short‐long sequences and a decrease for long‐short sequences that triggered intermittent 2:1 AV blocks. |
---|---|
ISSN: | 1045-3873 1540-8167 |
DOI: | 10.1111/j.1540-8167.1999.tb00647.x |