Silver-Coated Endotracheal Tubes and Incidence of Ventilator-Associated Pneumonia: The NASCENT Randomized Trial

CONTEXT Ventilator-associated pneumonia (VAP) causes substantial morbidity. A silver-coated endotracheal tube has been designed to reduce VAP incidence by preventing bacterial colonization and biofilm formation. OBJECTIVE To determine whether a silver-coated endotracheal tube would reduce the incide...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:JAMA : the journal of the American Medical Association 2008-08, Vol.300 (7), p.805-813
Hauptverfasser: Kollef, Marin H, Afessa, Bekele, Anzueto, Antonio, Veremakis, Christopher, Kerr, Kim M, Margolis, Benjamin D, Craven, Donald E, Roberts, Pamela R, Arroliga, Alejandro C, Hubmayr, Rolf D, Restrepo, Marcos I, Auger, William R, Schinner, Regina, NASCENT Investigation Group, for the
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:CONTEXT Ventilator-associated pneumonia (VAP) causes substantial morbidity. A silver-coated endotracheal tube has been designed to reduce VAP incidence by preventing bacterial colonization and biofilm formation. OBJECTIVE To determine whether a silver-coated endotracheal tube would reduce the incidence of microbiologically confirmed VAP. DESIGN, SETTING, AND PARTICIPANTS Prospective, randomized, single-blind, controlled study conducted in 54 centers in North America. A total of 9417 adult patients (≥18 years) were screened between 2002 and 2006. A total of 2003 patients expected to require mechanical ventilation for 24 hours or longer were randomized. INTERVENTION Patients were assigned to undergo intubation with 1 of 2 high-volume, low-pressure endotracheal tubes, similar except for a silver coating on the experimental tube. MAIN OUTCOME MEASURES Primary outcome was VAP incidence based on quantitative bronchoalveolar lavage fluid culture with 104 colony-forming units/mL or greater in patients intubated for 24 hours or longer. Other outcomes were VAP incidence in all intubated patients, time to VAP onset, length of intubation and duration of intensive care unit and hospital stay, mortality, and adverse events. RESULTS Among patients intubated for 24 hours or longer, rates of microbiologically confirmed VAP were 4.8% (37/766 patients; 95% confidence interval [CI], 3.4%-6.6%) in the group receiving the silver-coated tube and 7.5% (56/743; 95% CI, 5.7%-9.7%) (P = .03) in the group receiving the uncoated tube (all intubated patients, 3.8% [37/968; 95% CI, 2.7%-5.2%] and 5.8% [56/964; 95% CI, 4.4%-7.5%] [P = .04]), with a relative risk reduction of 35.9% (95% CI, 3.6%-69.0%; all intubated patients, 34.2% [95% CI, 1.2%-67.9%]). The silver-coated endotracheal tube was associated with delayed occurrence of VAP (P = .005). No statistically significant between-group differences were observed in durations of intubation, intensive care unit stay, and hospital stay; mortality; and frequency and severity of adverse events. CONCLUSION Patients receiving a silver-coated endotracheal tube had a statistically significant reduction in the incidence of VAP and delayed time to VAP occurrence compared with those receiving a similar, uncoated tube. TRIAL REGISTRATION clinicaltrials.gov Identifier: NCT00148642
ISSN:0098-7484
1538-3598
DOI:10.1001/jama.300.7.805