Determination of rat serum esterase activities by an HPLC method using S-acetylthiocholine iodide and p-nitrophenyl acetate

Establishing esterase assays allows the determination and comparison of esteratic activities of tissues of one organism and between organisms. We have developed a high-performance liquid chromatography (HPLC) assay for the determination of S-acetylthiocholine (ATC) and p-nitrophenyl acetate (NPA) hy...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical biochemistry 2008-10, Vol.381 (1), p.113-122
Hauptverfasser: Koitka, Matthias, Höchel, Joachim, Obst, Detlev, Rottmann, Antje, Gieschen, Hille, Borchert, Hans-Hubert
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Establishing esterase assays allows the determination and comparison of esteratic activities of tissues of one organism and between organisms. We have developed a high-performance liquid chromatography (HPLC) assay for the determination of S-acetylthiocholine (ATC) and p-nitrophenyl acetate (NPA) hydrolyzing activities of rat serum esterases based on ion pair chromatography with on-line radiochemical and ultraviolet (UV) detection. ATC is a substrate for cholinesterases, whereas NPA is cleaved by a variety of esterases and other proteins (e.g., cholinesterases, paraoxonase, carboxylesterase, albumin). Both substrates were incubated, simultaneously or separately, with rat serum to explore potential interferences between the enzymatic hydrolyses of the compounds. The ratio of the peak area of the 14C-labeled substrates to the total peak area of the substrates and their corresponding cleavage products was compared with the UV quantitation of ATC and p-nitrophenolate (NP), the cleavage product of NPA, measured at 230 and 350 nm, respectively. The peak identity of ATC and NP was confirmed by electrospray ionization–tandem mass spectrometry (ESI–MS/MS). The reaction rates of the assays using one substrate or both, as well as using radiochemical or UV detection, were equal. Moreover, the correlation between rat serum volumes and reaction rates was shown for both substrates. In conclusion, one can (i) choose between the two detection methods reliably, (ii) take advantage of monitoring both substrate and product by using radiochemical detection, and (iii) combine both substrates to determine esterase activities in rat serum and probably other biological matrices.
ISSN:0003-2697
1096-0309
DOI:10.1016/j.ab.2008.06.019