The Disruption of Murine Tumor Neovasculature by Low-intensity Ultrasound—Comparison Between 1- and 3-MHz Sonication Frequencies

Rationale and Objectives The goal was to determine whether the tumor vascular disrupting actions of low-intensity ultrasound were frequency dependent. Materials and Methods The effect of the frequency (1 MHz at 2.2 W/cm2 or 3 MHz at 2.4 W/cm2 ) of low-intensity ultrasound as a neovascular disrupting...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Academic radiology 2008-09, Vol.15 (9), p.1133-1141
Hauptverfasser: Wood, Andrew K.W., DVSc, PhD, Bunte, Ralph M., DVM, Price, Heather E., BS, Deitz, Margaret S., BS, Tsai, Jeff H., BS, Lee, William M.-F., MD, Sehgal, Chandra M., PhD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Rationale and Objectives The goal was to determine whether the tumor vascular disrupting actions of low-intensity ultrasound were frequency dependent. Materials and Methods The effect of the frequency (1 MHz at 2.2 W/cm2 or 3 MHz at 2.4 W/cm2 ) of low-intensity ultrasound as a neovascular disrupting modality was investigated in 15 murine melanomas (K173522 ) insonated for 3 minutes after the intravenous injection of a microbubble contrast agent (Definity). In contrast-enhanced power Doppler observations of each tumor (before and after treatment), measurements were made of the size of the area of the tumor that was perfused with blood containing the ultrasound contrast agent (percentage area of flow [PAF]), and the volume of contrast agent flowing through the unit volume of the tumor (color-weighted fractional area [CWFA]). During insonation of the tumor, the temperature was measured with a fine wire thermocouple in an additional eight mice. Results The antivascular action of low-intensity ultrasound was significantly enhanced (PAF by 64%; CWFA by 106%) when the tumor was treated with 3-MHz ultrasound rather than 1 MHz (analysis of variance: PAF, P = .02; CWFA, P = .04). The average rate of tumor temperature increase was 2.6 ± 1.3°C/min for 1 MHz and 5.0 ± 1.7°C/min for 3 MHz; these increases were significantly different ( P = .04). Conclusions Insonation of the tumor at a higher frequency amplified the heating of the neoplasm and led to greater disruption of the tumor vasculature; 3-MHz ultrasound was more efficacious than 1 MHz for antivascular cancer therapy.
ISSN:1076-6332
1878-4046
DOI:10.1016/j.acra.2008.04.012