Hydrogen peroxide for prevention of bacterial growth on polymer biomaterials

Background. Despite widespread use of potent antibiotics, infections of artificial implants and catheters are of increasing concern. We tested whether local treatment with 3% hydrogen peroxide (H2O2), long known as an inexpensive wound disinfectant, could prevent or reduce bacterial growth on polyme...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 1999-12, Vol.68 (6), p.2123-2128
Hauptverfasser: Alt, Eckhard, Leipold, Francesca, Milatovic, Danica, Lehmann, Günter, Heinz, Sybille, Schömig, Albert
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background. Despite widespread use of potent antibiotics, infections of artificial implants and catheters are of increasing concern. We tested whether local treatment with 3% hydrogen peroxide (H2O2), long known as an inexpensive wound disinfectant, could prevent or reduce bacterial growth on polymer biomaterials. Methods. Two-centimeter-long pieces of polyurethane and silicone tubing were contaminated with a standardized solution of Staphylococcus epidermidis (105/mL) and then rinsed and wiped with saline (0.9%) solution. Bacterial growth was assessed after incubation at 37°C for 24 hours. Bacterial colonies were compared for the following treatments: wiping only with saline; wiping with 1.5%, 2%, or 3% H2O2; pretreating biomaterials with 3% H2O2 and subsequent contamination for 2 and 4 hours without treatment after contamination; and contamination of tubings 1 month after pretreatment with 3% H2O2. The effect of 3% H2O2 was also assessed on contamination with Escherichia coli. Results. Bacterial growth was reduced by more than 99% when the contaminated tubes were treated with 3% H2O2 compared with saline control (p < 0.001). Lower concentrations of H2O2 were less effective. The length of the contamination period had no influence on the effectiveness of H2O2 when used on polyurethane but did with silicone tubings. Pretreatment with H2O2 1 month before contamination still reduced bacterial growth rate by 90% on polyurethane and by 75% on silicone tubings. Comparable effects on bacterial growth rate were observed for staphylococci (−90%, p < 0.001) and escherichiae (−90%, p < 0.001). Conclusions. Local treatment with 3% H2O2 significantly reduced bacterial growth on polymer biomaterials even for 1 month after treatment. This finding might influence clinical strategies of prevention of foreign body infection.
ISSN:0003-4975
1552-6259
DOI:10.1016/S0003-4975(99)00832-2