Gas Chromatographic–Tandem Mass Spectrometric Quantification of Free 3-Nitrotyrosine in Human Plasma at the Basal State

A fully validated gas chromatographic–tandem mass spectrometric (GC–tandem MS) method for the accurate and precise quantification of free 3-nitrotyrosine in human plasma at the basal state is described. In the plasma of 11 healthy humans a mean concentration of 2.8 nM (range 1.4–4.2 nM) for free 3-n...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analytical biochemistry 1999-12, Vol.276 (2), p.195-203
Hauptverfasser: Schwedhelm, Edzard, Tsikas, Dimitrios, Gutzki, Frank-Mathias, Frölich, Jürgen C.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A fully validated gas chromatographic–tandem mass spectrometric (GC–tandem MS) method for the accurate and precise quantification of free 3-nitrotyrosine in human plasma at the basal state is described. In the plasma of 11 healthy humans a mean concentration of 2.8 nM (range 1.4–4.2 nM) for free 3-nitrotyrosine was determined by this method. This is the lowest concentration reported for free 3-nitrotyrosine in plasma of healthy humans. The presence of endogenous free 3-nitrotyrosine in human plasma was unequivocally shown by generating a daughter mass spectrum. Various precautions had to be taken to avoid artifactual formation of 3-nitrotyrosine from nitrate during sample treatment. Endogenous plasma 3-nitrotyrosine and 3-nitro-l-[2H3]tyrosine added for use as internal standard were isolated by high-performance liquid chromatographic (HPLC) analysis of 200-μl aliquots of plasma ultrafiltrate samples (20 kDa cut-off), extracted from a single HPLC fraction by solid-phase extraction, derivatized to their n-propyl ester–pentafluoropropionyl amide–trimethylsilyl ether derivatives, and quantified by GC–tandem MS. Overall recovery was determined as 50 ± 5% using 3-nitro-l-[14C9]tyrosine. The limit of detection of the method was 4 amol of 3-nitrotyrosine, while the limit of quantitation was 125 pM using 3-nitro-l-[14C9]tyrosine. 3-Nitrotyrosine added to human plasma at 1 nM was quantitated with an accuracy of ≥80% and a precision of ≥94%. The method should be useful to investigate the utility of plasma free 3-nitrotyrosine as an indicator of nitric oxide (•NO)-associated oxidative stress in vivo in humans.
ISSN:0003-2697
1096-0309
DOI:10.1006/abio.1999.4361