Long-term endothelial dysfunction after coronary artery stenting

OBJECTIVES We assessed the endothelial-dependent vasomotor function in nonrestenotic coronary arteries more than six months following stent implantation, balloon angioplasty (BA), and directional atherectomy (DCA). BACKGROUND Catheter-based coronary interventions are associated with extensive arteri...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the American College of Cardiology 1999-11, Vol.34 (6), p.1675-1679
Hauptverfasser: Caramori, Paulo R.A, Lima, Valter C, Seidelin, Peter H, Newton, Gary E, Parker, John D, Adelman, Allan G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:OBJECTIVES We assessed the endothelial-dependent vasomotor function in nonrestenotic coronary arteries more than six months following stent implantation, balloon angioplasty (BA), and directional atherectomy (DCA). BACKGROUND Catheter-based coronary interventions are associated with extensive arterial injury. Endothelial function has been shown to remain chronically abnormal after vascular injury. The long-term effects of different percutaneous coronary interventions on endothelial function are not known. METHODS Thirty-nine patients treated at least six months earlier with a coronary intervention for isolated proximal left anterior descending (LAD) stenosis, with no evidence of restenosis, were studied. Twelve patients had been stented, 15 had been treated with BA, and 12 had undergone DCA. Changes in diameter of the intervened LAD, and the unintervened circumflex coronary artery (Cx), in response to intracoronary acetylcholine infusions were assessed by quantitative angiography. RESULTS The groups had similar angiographic characteristics and risk factors for endothelial dysfunction. The LAD constricted significantly more (p = 0.02) in previously stented patients (−21.8 ± 4.3%), as compared to patients previously treated with BA (−9.5 ± 2.8%) or with DCA (−9.1 ± 3.6%). In contrast, acetylcholine infusion resulted in mild constriction in the Cx, which was similar in the three groups (p = 0.47). By multiple regression analysis, previous implant of a stent was the only significant predictor of LAD constriction (p = 0.008). CONCLUSIONS More severe endothelial dysfunction was observed long term after stenting as compared to BA or DCA. These findings may have implications with respect to the progression of atherosclerosis in coronary arteries subjected to percutaneous interventions.
ISSN:0735-1097
1558-3597
DOI:10.1016/S0735-1097(99)00411-8