The evaluation of resin composite consistency
Objective. To evaluate a method for the assessment of the consistency of unset resin composite. Methods. Fourteen commercial resin composites were selected, which had a range of consistencies as assessed subjectively. The material was placed in a cylindrical mold with 8 mm diameter and 8 mm depth, a...
Gespeichert in:
Veröffentlicht in: | Dental materials 1998-11, Vol.14 (6), p.424-428 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Objective. To evaluate a method for the assessment of the consistency of unset resin composite.
Methods. Fourteen commercial resin composites were selected, which had a range of consistencies as assessed subjectively. The material was placed in a cylindrical mold with 8
mm diameter and 8
mm depth, and a glass rod with 4.37
mm diameter driven into the composite at 24.4
mm
min
−1 for 6
s, i.e., to a depth of 2.44
mm. The maximum force reached during the 6
s period was recorded, and used as a measure of consistency.
Results. Consistency values ranged from 0.33
N to 31.3
N, with the highest values being found for some of the recently introduced `packable' materials. The reliability of the test was high.
Significance. The test may be useful as a standard method of assessing resin composite consistency. |
---|---|
ISSN: | 0109-5641 1879-0097 |