Successful Treatment of Infected Ascending Aortic Prosthesis by Omental Wrapping Without Graft Removal

A deep wound infection after a midline sternotomy is a very serious complication. The severity of it can be increased by the presence of prosthetic material. We present a case of a 76-year-old man who had an infection of an ascending aortic graft develop after a Bentall procedure. Rather than follow...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 2008-07, Vol.86 (1), p.287-289
Hauptverfasser: Samoukovic, Gordan, MD, Bernier, Pierre-Luc, MD, Lachapelle, Kevin, MD
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A deep wound infection after a midline sternotomy is a very serious complication. The severity of it can be increased by the presence of prosthetic material. We present a case of a 76-year-old man who had an infection of an ascending aortic graft develop after a Bentall procedure. Rather than following the “traditional” surgical therapy of graft explantation and debridement, we chose to preserve the graft and protect it by omental translocation. The relative merits of this therapeutic approach are outlined and discussed. The patient was discharged on the postoperative day 6 after an uneventful postoperative course.
ISSN:0003-4975
1552-6259
DOI:10.1016/j.athoracsur.2008.01.086