Fluorometric microassays for the determination of cathepsin L and cathepsin S activities in tissue extracts
We established a continuous semi-microassay, and for large-scale studies both a stopped and a continuous microtiter plate assay for the fluorometric determination of cathepsin L and cathepsin S activities in body fluids, tissues or cell extracts in the presence of cathepsin B. For the detection of e...
Gespeichert in:
Veröffentlicht in: | Biological chemistry 1999-09, Vol.380 (9), p.1109-1116 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We established a continuous semi-microassay, and for large-scale studies both a stopped and a continuous microtiter plate assay for the fluorometric determination of cathepsin L and cathepsin S activities in body fluids, tissues or cell extracts in the presence of cathepsin B. For the detection of enzymatic activities we used the synthetic substrate Z-Phe-Arg-AMC, and for discrimination between cathepsin L, S and cathepsin B the specific inhibitor CA-074 for blocking interfering cathepsin B activities was applied. Furthermore, we took advantage of the stability of cathepsin S at pH 7.5 for further differentiation between cathepsin L and cathepsin S activities. The kinetic assays were characterized in terms of imprecision, analytical sensitivity, accuracy and substrate concentration. The within-run coefficients of variation were found to be 4.9%-7.2% for the continuous semi-microassay, 10.3%-11.7% for the stopped, and 4.5%-11.8% for the continuous microtiter plate assay. The between-days coefficients of variation for the continuous semi-microassay were 8.1%-8.9%, while for the stopped and continuous microtiter plate assays the coefficients were 11.2%-13.5% and 5.8%-12.2%, respectively. Compared to the continuous semi-microassay, the stopped and the continuous microtiter plate assays showed 3-fold and 11-fold higher sensitivity, respectively. Comparison between the continuous enzyme activity assays at substrate concentrations of 40 microM and 200 microM demonstrated a significant correlation of r = 0.97 and r = 0.99, respectively. The newly developed microtiter plate assay will allow efficient, sensitive and high precision determination of cathepsin L and cathepsin S activities in large-scale studies of cysteine-cathepsin dependent diseases. |
---|---|
ISSN: | 1431-6730 |
DOI: | 10.1515/bc.1999.138 |