Confrontation of the radiographic preoperative planning with the postoperative data for uncemented total hip arthroplasty

For hip prosthesis surgery, the challenge is to obtain optimal function of the instrumented hip but also to eliminate any limb length discrepancy, correct the femur offset and guarantee the center of rotation of the hip joint. Preoperative planning for total hip arthroplasty (THA) enables determinat...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Revue de chirurgie orthopédique et réparatrice de l'apparell moteur 2008-06, Vol.94 (4), p.368-375
Hauptverfasser: Debarge, R, Lustig, S, Neyret, P, Ait Si Selmi, T
Format: Artikel
Sprache:fre
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:For hip prosthesis surgery, the challenge is to obtain optimal function of the instrumented hip but also to eliminate any limb length discrepancy, correct the femur offset and guarantee the center of rotation of the hip joint. Preoperative planning for total hip arthroplasty (THA) enables determination of the appropriate length for the prosthetic neck and the size and eventually the type of implants to use. From a prospective series of 86 patients who underwent first-intention THA for implantation of a noncemented prosthesis, we studied the precision of the outcome as function of the preoperative planning. We also ascertained whether the preoperative planning was sufficient to provide the measurements necessary for correct implant position. We analyzed a prospective series of patients who underwent first-intention THA from January 2004 through January 2006. To be eligible for inclusion, patients could not have a THA of the contralateral hip. The series was composed of 58 females and 28 males, mean age 70.2 years (range 45-93). The reasons for THA were primary degenerative disease (n=76) and aseptic osteonecrosis (n=10). The contalateral hip was intact and free of osteoarthritis with an anatomic presentation considered to be normal. The standard X-ray protocol included an anteroposterior view of the pelvis in the upright position and 10 degrees internal rotation obtained preoperatively and three months postoperatively. All radiographic measurements were made by the same investigator using a manual nondigitalized technique. We compared planning parameters (pivot size and type, length of the neck, and size of the cup) with the final outcome in order to determine the compliance with the preoperative planning. All operations were performed in the lateral supine position under general anesthesia and by the same surgeon. The posterolateral Moore approach was used. All implants were press fit without cement, both for the cup and for the femoral piece. All planning parameters selected for study (offset, size of the head and the cup, length of the neck) were available for 32 hips, giving an overall conformity of 37%. The length of the neck was as planned in 75% of hips, the size of the cup in 62% and the size of the femoral stem in 64%. The offset defined preoperatively was never changed during the operation. Ideal implantation (+/- 5mm for all criteria selected for study) was obtained in 60% of hips; the height of the center of rotation was reproduced in 81% and th
ISSN:0035-1040
DOI:10.1016/j.rco.2007.07.004